OpenBuildings™ Designer 帮助

Transverse Section Middle Zone Reinforcement Callout

The middle zone of the column’s transverse reinforcements is annotated with a callout that uses the following syntax:
  • Size @Spacing
  • 偏移
In this format string, Size is replaced by the bar designation and Spacing is replaced by the bar spacing formatted using the active coordinate readout.If there are three zones, the Offset is replaced by the callout BAL, indicating the remaining portion of the column contains the reinforcements specified in the first part of the callout.If there is only one zone, and its transverse section is constant through the entire length of the column, there is no value displayed for Offset.If there is only one zone, and its transverse section is not constant through the entire length of the column, the distance from the bottom of the column to the end of the zone boundary is displayed.The information displayed in the callout is derived from values assigned to ISM reinforcement properties.
注释: No graphic cells are used to represent transverse sections in the schedule table.Instead, the Section Legend portion of the Concrete Column Schedule view provides a graphic representation of the transverse reinforcement pattern in the column.
Callout Example ISM PropertySize Value displayed string ISM PropertySpacing Valuedisplayed string ISM PropertyOffset Valuecomputed value
#4 @4BAL 材料 (#4-60ksi)(RebarMaterial)a0fd36b6-d2aa-4866-92b0-1453109e66c4 间距 6 Layout Path (0,0,18.33)(0,0,25.67)
  #4   6   BAL


注释: When applicable, the Layout Path “Z” coordinates determine the extents of the zone.The difference between them is used to calculate the displayed offset.